Инженерный калькулятор

Bleeder Resistor and Capacitor Discharge Calculator

ВН+CRbV0safe touch voltaget = RC ln(V0 / Vsafe)tV(т)

How to read the diagram. The bleeder resistor sits directly across the capacitor, so the stored charge drains through it once the supply is removed. The curve is V = V0 × e−t/RC; the dashed line is the voltage that is safe to touch, and where the curve crosses it is the discharge time.

A high voltage capacitor stays charged after the supply is removed. This calculator gives the discharge time through a bleeder resistor, the resistance required to reach a target voltage in a given time, and the stored energy that has to be dissipated while it happens.

входные

Результаты

Time constant (R×C)
-
Время разряда
-
Накопленная энергия
-
Initial bleeder power
-
R for 60 s to 60 V
-

Формула

V(t) = V0 × e^(−t / RC). Discharge time to a target voltage is t = R × C × ln(V0 / Vt). Stored energy is E = ½ × C × V0². The initial power in the bleeder is V0² / R, and it falls as the capacitor discharges.

What the calculator does not include

Safety reference

IEC 62368-1 treats a capacitor as hazardous above 60 V DC or 20 J stored energy, and requires discharge to a safe level within a defined time after the supply is removed. The exact limit depends on the equipment class and the accessible part; the numbers above let you check the design against whichever limit applies. This page is a calculation aid, not a compliance statement.

Choosing the bleeder

Bleeder duty is continuous voltage with low current, so the resistor is usually a planar or tube thick film part with a high resistance value. Where the bank voltage exceeds a single resistor, the string is split and each element is rated for its share — see the Обзор резисторов.

Send the capacitance, voltage and target discharge time: запросить техническое предложение, response within 6 hours.